Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Hand Surg Rehabil ; 42(6): 549-552, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37714516

RESUMO

Cutaneous myoepithelioma is a rare neoplasm of the skin that has become more widely recognized in recent years despite significant diagnostic pitfalls. It is a benign neoplasm with a high recurrence rate if not excised radically, and must be distinguished from its malignant counterpart. Few cases have been described so far and, to our knowledge, no cases in the finger of a child exist in the literature. We report the case of a 15 year-old boy affected by a rare form of locally aggressive spindle-cell myoepithelioma, and suggest a new multidisciplinary approach combining surgical excision and custom brachytherapy.


Assuntos
Mioepitelioma , Neoplasias Cutâneas , Masculino , Criança , Humanos , Adolescente , Mioepitelioma/cirurgia , Mioepitelioma/diagnóstico , Mioepitelioma/patologia , Neoplasias Cutâneas/cirurgia , Neoplasias Cutâneas/patologia , Dedos , Extremidade Superior/patologia
2.
Medicine (Baltimore) ; 94(12): e476, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25816026

RESUMO

Temozolomide is the current standard of therapy for postoperative patients with glioblastoma starting adjuvant radiotherapy. Hematologic adverse events are the most frequent side effects of temozolomide, while liver toxicity has been reported only in the post-marketing period. Here we report a case of severe temozolomide-induced liver injury during concurrent radiotherapy treatment, at a dose level of 75 mg/m2. The aim of this case report is to focus on the problems of temozolomide-induced hepatotoxicity. In conclusion, a close monitoring of liver function tests is recommended during treatment with temozolomide.


Assuntos
Antineoplásicos Alquilantes/efeitos adversos , Doença Hepática Induzida por Substâncias e Drogas/etiologia , Colestase/induzido quimicamente , Dacarbazina/análogos & derivados , Idoso , Antineoplásicos Alquilantes/administração & dosagem , Neoplasias Encefálicas/tratamento farmacológico , Doença Hepática Induzida por Substâncias e Drogas/diagnóstico , Dacarbazina/administração & dosagem , Dacarbazina/efeitos adversos , Evolução Fatal , Glioblastoma/tratamento farmacológico , Humanos , Masculino , Temozolomida
3.
Phys Med Biol ; 52(16): 5101-17, 2007 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-17671356

RESUMO

This work reports the results of the application of a practical method to determine the in vivo dose at the isocenter point, D(iso), of brain thorax and pelvic treatments using a transit signal S(t). The use of a stable detector for the measurement of the signal S(t) (obtained by the x-ray beam transmitted through the patient) reduces many of the disadvantages associated with the use of solid-state detectors positioned on the patient as their periodic recalibration, and their positioning is time consuming. The method makes use of a set of correlation functions, obtained by the ratio between S(t) and the mid-plane dose value, D(m), in standard water-equivalent phantoms, both determined along the beam central axis. The in vivo measurement of D(iso) required the determination of the water-equivalent thickness of the patient along the beam central axis by the treatment planning system that uses the electron densities supplied by calibrated Hounsfield numbers of the computed tomography scanner. This way it is, therefore, possible to compare D(iso) with the stated doses, D(iso,TPS), generally used by the treatment planning system for the determination of the monitor units. The method was applied in five Italian centers that used beams of 6 MV, 10 MV, 15 MV x-rays and (60)Co gamma-rays. In particular, in four centers small ion-chambers were positioned below the patient and used for the S(t) measurement. In only one center, the S(t) signals were obtained directly by the central pixels of an EPID (electronic portal imaging device) equipped with commercial software that enabled its use as a stable detector. In the four centers where an ion-chamber was positioned on the EPID, 60 pelvic treatments were followed for two fields, an anterior-posterior or a posterior-anterior irradiation and a lateral-lateral irradiation. Moreover, ten brain tumors were checked for a lateral-lateral irradiation, and five lung tumors carried out with three irradiations with different gantry angles were followed. One center used the EPID as a detector for the S(t) measurement and five pelvic treatments with six fields (many with oblique incidence) were followed. These last results are reported together with those obtained in the same center during a pilot study on ten pelvic treatments carried out by four orthogonal fields. The tolerance/action levels for every radiotherapy fraction were 4% and 5% for the brain (symmetric inhomogeneities) and thorax/pelvic (asymmetric inhomogeneities) irradiations, respectively. This way the variations between the total measured and prescribed doses at the isocenter point in five fractions were well within 2% for the brain treatment, and 4% for thorax/pelvic treatments. Only 4 out of 90 patients needed new replanning, 2 patients of which needed a new CT scan.


Assuntos
Algoritmos , Neoplasias Encefálicas/radioterapia , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Neoplasias Torácicas/radioterapia , Humanos , Dosagem Radioterapêutica
4.
Med Phys ; 33(11): 4414-22, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17153420

RESUMO

A method for the in vivo determination of the isocenter dose, Diso, and mid-plane dose, Dm, using the transmitted signal St measured by 25 central pixels of an aSi-based EPID is here reported. The method has been applied to check the conformal radiotherapy of pelvic tumors and supplies accurate in vivo dosimetry avoiding many of the disadvantages associated with the use of two diode detectors (at the entrance and exit of the patient) as their periodic recalibration and their positioning. Irradiating water-equivalent phantoms of different thicknesses, a set of correlation functions F(w, l) were obtained by the ratio between St and Dm as a function of the phantom thickness, w, for a different field width, l. For the in vivo determination of Diso and Dm values, the water-equivalent thickness of the patients (along the beam central axis) was evaluated by means of the treatment planning system that uses CT scans calibrated in terms of the electron densities. The Diso and Dm values experimentally determined were compared with the stated doses D(iso,TPS) and D(m,TPS), determined by the treatment planning system for ten pelvic treatments. In particular, for each treatment four fields were checked in six fractions. In these conditions the agreement between the in vivo dosimetry and stated doses at the isocenter point were within 3%. Comparing the 480 dose values obtained in this work with those obtained for 30 patients tested with a similar method, which made use of a small ion-chamber positioned on the EPIDs to obtain the transmitted signal, a similar agreement was observed. The method here proposed is very practical and can be applied in every treatment fraction, supplying useful information about eventual patient dose variations due to the incorrect application of the quality assurance program based on the check of patient setup, machine setting, and calculations.


Assuntos
Neoplasias Pélvicas/radioterapia , Sistemas de Informação em Radiologia/instrumentação , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/instrumentação , Humanos , Radiometria/métodos , Radioterapia Conformacional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Silício/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA